The optical beam smoke detector works on the principle of light obscuration.
Optical beam smoke detector.
With only one device to install and align these single ended optical beam solutions save you time and money on open area and high ceiling applications.
They are used to detect fires in buildings where standard point smoke detectors would either be uneconomical or restricted for use by the height of the building.
If smoke is present in the air then this obscures or blocks the light received by the receiver lowering the amount of light.
Guide to using optical beam smoke detection optical beam detection provides an economical solution for detecting smoke in large open space areas such as shopping malls warehouses and airports.
An optical beam smoke detector is a device that uses a projected beam of light to detect smoke across large areas typically as an indicator of fire.
The receiver is calibrated to a preset sensitivity level based on a percentage of total obscuration.
A beam smoke detector works on the principle of obscuration.
The photosensitive element of the optical beam smoke detector sees light produced by the transmitter in a normal condition.
The object includes parametric values for transmitter and reflector radius and depth beam range and coverage area.
An optical beam smoke detector is a device that uses a projected beam of light to detect smoke across large areas typically as an indicator of fire.
The beam detector sends out an invisible infra red ir beam of light that the receiver measures.
With only one device to install and align these single ended optical beam solutions saves you time and money on large area applications.
Reflected beam smoke detectors are designed for spacious rooms open areas and high ceilings.
Generic optical beam smoke detector with transmitter and reflector.
Optical beam smoke detectors are often installed in warehouses as a cost effective means of protecting large open spaces.
An optical smoke alarm also called photo electric smoke alarm works using the light scatter principle.
Single ended reflected type design.
16 to 328 foot protection range.
They are used to detect fires in buildings where standard point smoke detectors would either be uneconomical or restricted for use by the height of the building.
The new simplex addressable beam detector combines the power and flexibility of idnet technology with the proven performance of the fireray 5000 optical beam smoke detector.
Unlike traditional detection systems reflected beam smoke detectors were designed for spacious rooms open areas and high ceilings.
The alarm contains a pulsed infra red led which pulses a beam of light into the sensor chamber every 10 seconds to check for smoke particles.