Roof Drain Conductor Sizing

Iapmo

Iapmo

Chapter 11 Storm Drainage California Plumbing Code 2016 Upcodes

Chapter 11 Storm Drainage California Plumbing Code 2016 Upcodes

Chapter 11 Storm Drainage Nyc Plumbing Code 2014 Upcodes

Chapter 11 Storm Drainage Nyc Plumbing Code 2014 Upcodes

Calculating Roof Area

Calculating Roof Area

Roofing Prevent Roofing Structure And Membrane Failure 8212 Selection Of A Roof Drainage System Is Important To Your Building S Long Term Success Plant Services

Roofing Prevent Roofing Structure And Membrane Failure 8212 Selection Of A Roof Drainage System Is Important To Your Building S Long Term Success Plant Services

Stormwater Conductors

Stormwater Conductors

Stormwater Conductors

The flow rate in storm drain piping shall not exceed that specified in table 1106 2.

Roof drain conductor sizing.

The flow through the roof drain is very efficient directing the water into the drain. The result is the number of drains needed. Calculate total roof area. Section 101 5 of the ipc tells us not to reduce the pipe size in the direction of flow.

4 to avoid severe hydraulic jump and or backpressure good engineering practice requires the vertical leader transition into a larger size horizontal storm drain per the gpm flow indicated in table 2 for 1 8 and 1 4 sloped storm drains. To size the vertical roof drain for the same parameters 5 000 square feet of room area and 6 per hour of rain consult table 1106 2 figure 3. As it turns out the opposite is true of most roof drains. The sizing of roof drains must be large enough to quickly carry away all water entering the roof drains.

Table 1106 2 storm drain pipe sizing for si. From figure 1108 4 the 100 year 60 minute precipitation is 3 75 inches per hour. 50 000 4 400 11 36. When sizing roof drains the limiting factor for the amount of water each drain will carry away is the size of leader therefore increasing leader size decreases the number of drains required.

Step by step sizing of zurn drains step 1 a. But this isn t the whole story. Take the roof s total square footage and divide by the total square footage handled by one drain. Or smaller in size have the ability to flow more water to the piping than the piping can handle using 33 for the vertical and full flow for the horizontal.

Example roof plan 4 a 101 2 solution. Vertical and horizontal storm drain piping shall be sized based on the flow rate through the roof drain. Or 12 drains required. The full flow capacity of a drain is not realized until the water reaches approximately 2 5 above the inlet in a four inch drain and 3 5 in a six inch drain.

The next step is to determine each roof area that will be served by a separate leader drain pipe scupper or downspout. The end result is roof drains 6 in. Each 4 drain size in a 6 hourly rainfall area will accommodate drainage of 3 070 sq. The first step in sizing a roof drain is to calculate the surface area of the roof that the drains will be covering as well as the average hourly rainfall rate at the building location.

Factors which affect proper roof drainage are deck slope drain size and placement of drains. To convert to an area for a 4 inch per hour rainfall to enter table 1108 1 do this. This reveals that the minimum size for the leader pipe is 5. 1 inch 25 4 mm 1 foot 304 8 mm 1 gallon per minute 3 785 l m.

The sizing for the horizontal piping is based on the pipes flowing full.

Chapter 3 1 Storm Drainage Sizing Building Drain Sewer Building Drain That Part Of The Lowest Piping Of A Drainage System That Receives The Discharge Ppt Download

Chapter 3 1 Storm Drainage Sizing Building Drain Sewer Building Drain That Part Of The Lowest Piping Of A Drainage System That Receives The Discharge Ppt Download

Conductor Heads Saf Southern Aluminum Finishing Co Inc

Conductor Heads Saf Southern Aluminum Finishing Co Inc

Https Portal Ct Gov Media Dcp Pdf Occpro Pdf Ceu201213stormdrainagesizingpdf Pdf La En

Https Portal Ct Gov Media Dcp Pdf Occpro Pdf Ceu201213stormdrainagesizingpdf Pdf La En

Http Www Mdboa Com Files 2015 Ipc Design Installation And Inspection Principles Pdf

Http Www Mdboa Com Files 2015 Ipc Design Installation And Inspection Principles Pdf

Source : pinterest.com